Showing results: 166 - 180 of 228 items found.
-
TCVR Series -
EM Research, Inc.
*4-wire SPI (3.3 V Logic) digital interface *-45 C° to +85 C° *4 W linear power T*ransceiver pair support dual polarization *Low EVM% *Outdoor unit IP68 compliant *Compliant to RTCA-DO-160G *Concept/Eval Unit Tested to 1024-QAM
-
VAM100 -
Axiomtek Co., Ltd.
*4 4-wire Isolated RS-232/422/485*Swappable modular design*Maximize I/O flexibility*2kV isolated protection*Designed for tBOX300/500 series*LVD, FCC, EN 50155 and IEC 60945 certified; CE compliant
-
VAM900 -
Axiomtek Co., Ltd.
*1 4-wire isolated RS-232/422/485, 1 isolated CANBus 2.0A/B, 1 isolated DIO 8-in/8-out*Swappable modular design*Maximize I/O flexibility*2kV (COM & CANBus)/1.5 kV (DIO) isolated protection*Designed for tBOX300/500 series*EN 50155 certified; CE, LVD and FCC compliant
-
ABB Ltd.
ABB conductivity analyzers are designed to meet the most exacting requirements of our valued customers. The extensive range covers 2 and 4-wire analyzers and single or dual-input devices.
-
19036 -
Chroma ATE Inc.
Chroma 19036 is the industry's first wound component electrical safety test (EST) analyzer that combines the functions of impulse test, hipot, insulation resistance and DC resistance measurements. It has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement that can comply with the wound components test demands by providing maximum 10 channels output for multichannel scanning tests to save time and labor costs.
-
CBT4 -
Shanghai Powoo Industry Develop Group Limited
- Completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - more space in meter can be saved with combined current transformer in comparison to that of the same number of single form current transformers; - HLX-2 is used for 3-phase-3-wire circuits; HLX-3 is used for 3-phase-4-wire circuits;
-
KT-96CR -
KILTER ELECTRONIC CO.,LTD
Range: 60m / 600m / 6km / 60km(197ft-197,000 ft)Resistance: 600mΩ -- 600ΩAccuracy: ±1.5% reading ±3 digits;Resolution:RES Mode 0.01mΩ Cap Mode 0.01mwire guage: 0~26 (ga).material:Al /CuAuto range;Backlight controlResistance & Capacitance measurementSelf- calibrating function;Use a standard cable or a known length cable to calibrate;Auto save the parameter of the cable;Applicable for any type and any size of cable;Transform resistance of wire and capacitance between two wires to length;4-wire vector measurement, high accuracy and resolution.Unit: m / km; ft
-
CB52 -
CAMI Research Inc. (CableEye®)
The CB52 is intended for periodic calibration verification of the Kelvin 4-wire resistance measurement module – an optional, add-on module that may be purchased with any new hipot system, or added to an existing high voltage tester as an upgrade. To ensure that 4-wire resistance measurements remain accurate, CAMI recommends running the verification check every quarter. A 4-wire measurement module that is out of calibration will give inaccurate results. Some (maybe all) resistance measurements will be incorrect. Consequently, it may Pass what should Fail and, conversely, Fail what should Pass. In other words product yield will be contaminated due to unreliable measurements.
-
MPR-601W-01 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and *3phase 3wires and 3phase 4wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
ProDAQ 5821 -
Bustec Ltd.
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
V460 -
Highland Technology, Inc.
The V460 is a VME-based versatile source/measurement unit. It includes a programmable constant-current source, a precision programmable gain 16-bit analog-to-digital converter, and a 4-wire, 16-channel analog multiplexer. An internal microprocessor supervises channel scanning according to user loaded parameters, reporting sensor voltage drops or, for selected sensor types, engineering-unit data.
-
-
RT1 -
North Atlantic Industries
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Model 2399 -
ICS Electronics
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
Temperature -
Reach Technologies Inc.
Reach Technologies' CAN Temperature Sensor Interface sources, conditions and digitizes 8 temperature sensor inputs for collection via CAN. The module is ideal for conveniently adding temperature data to a distributed CAN network. The CAN Temperature Sensor Interface is configurable via a CANopen stack, and is available in a 4-wire RTD and thermocouple variants.